Model No.
Length (mm)
Accuracy
Max Operation Range
Measured Torque Range
Resolution
Data Memory Size
PC Connectivity
DC2-030AR
390
CW: +/-1% CCW: +/-2%
30 N-m 22.12 ft-lb 265.5 in-lb
306.1 kg-cm
1.5~30 N-m 1.11~22.12 ft-lb 13.3~265.5 in-lb
15.3~306.1 kg-cm
0.01 N-m 0.01 ft-lb 0.1 in-lb 0.1 kg-cm
250
Yes
* Accuracy is guaranteed from 20% to 100% full scale.
* C: +/-3%, N: No communication, R: With communication
Specifications
All Models
Bright LED
2 LED (1 Red+ 1 Green)
Pre-setting No.
9 sets
Operation Mode
Peak hold / Track
Unit Selection
N-m, in-lb, ft-lb, kg-cm
Head Type
Interchangeable Head
Button
5
Battery
AA × 2
Battery Life (Continuous operation)
110 hrs.
Battery Life (Standby)
1 year
Operating Temperature
-10˚C~60˚C
Storage Temperature
-20˚C~70˚C
Humidity
Up to 90 % non-condensing
Drop Test
1 m
Vibration Test
10G
Life Time
10000 cycle
Environmental Test
Pass
Electromagnetic Compatibility Test